THERMAL INSULATION OF BUILDINGS

"JUODASIS GINTARAS Ltd." - EXPERTS OF INSULATION

Since the very beginning of our activity we started specializing in the field of thermal foam insulation of buildings.
In 1994 we were among the first companies in Lithuania to introduce Danish technology of filling air cavities in the walls with aminoplast foam for thermal insulation, which we have been successfully working with so far. More >>

In autumn 2007 we were among the first companies in Europe that became exclusive dealers for Canadian company ICYNENE Inc. and started to implement this unique technology of comprehensive thermal insulation with special ICYNENE® soft foam in the Baltics and Poland. More >>

The building technical regulations that are in force at present require heat resistance as follows: not less than 6.24 m2K/W for the roof, not less than 5.25 m2K/W for external walls, and not less than 4.54 m2K/W for the floor. However, according to the

research results, influence of heat resistance of partitions on energy efficiency is considerably smaller than that of creating a barrier preventing large amounts of warm air from leaking through the elements of the structure.

It is the successful solution of this task what the thermal foam insulation technologies we use help to achieve.

The technology of thermal insulation with aminoplast foam is developed specially for filling empty air cavities in external walls. This thermal foam prevents warm air from rising up and stops the active process of warmth leakage shown in picture 1.

It is obvious that thermal insulation of walls from the outside leaving an empty air cavity is absolutely irrational, since air convection, carrying out about 80% of warmth from premises, is not stopped.

The technology of thermal insulation with GAMO foam is developed for comprehensive thermal insulation of buildings. This thermal foam is sprayed onto the surface or into the air cavities. Its very good airtightightness allows to prevent most of the warmth from leaking out of the premises. This fact is

confirmed by the results of the research on dependence of energy efficiency on the thickness of the layer of GAMO foam, presented in table 1.

Picture 1. Scheme of warmth leakage through the wall with an empty air cavity.

Šilumos išėjimo per sieną su tuščiu oro tarpu schema

www.gamo.lt
www.icynene.com

"JUODASIS GINTARAS Ltd." - EXPERTS OF INSULATION Everyone can consult about thermal insulating to our specialists for free.
Call: +370 686 78080.


Table 1. Results of research on dependence of energy efficiency on the thickness of the layer of GAMO foam

Thickness of the layer
of GAMO foam δ (cm)
Heat resistance of the layer of GAMO foam R-value (m2K/W) Energy efficiency (%)

2,5 0,65 80
10 2,36 94
15 3,68 96
20 5,26 97
25 6,58 98

30

7,9

98

 

 
en lt lv ru
Thermal insulation of buildings thermal insulation of sloped roofs external thermal insulation of walls thermal insulation of walls with aminoplast foam sprayed into air cavities Internal thermal insulation of walls thermal insulation of the ceiling thermal insulation of internal partitions thermal insulation of the floor
Plastic windows, rollers Doors Garage gates Sliding systems External security roller shutters
 
 
© 2008 UAB „Juodasis gintaras”
Draugystes str. 20, LT 89167
Mazeikiai, Lithuania
Tel./fax +370 443 26651;
E-mail: info@juodasisgintaras.lt
Gamo Gazele
Solution by